Above-Ground Fuel Tank Selection Guide

O

Hurtado.cc provides above-ground fuel storage tanks built in accordance with two distinct Steel Tank Institute specifications: Flameshield and Fireguard.  Each is offered with a 30-year structural warranty supported by the Steel Tank Institute.

Please select either design to review applicable features and specifications:

Flameshield (meets UL142, double wall and 2-hr fire-resistant)

Fireguard (meets UL2085, double wall, 2-hr fire, impact and ballistic resistant)

Also available:

  • Rectangular tanks.
  • Dispensing equipment for fleet vehicles or plant operations.
  • Customized electronic level sensors, pumps and accessories.
  • Split tanks for consolidated fuel inventory.

 

Flameshield Features:
200-4,000 gallon capacity
Flameshield Features:
5,000-25,000 gallon capacity
  • Double wall, cylindrical or rectangular construction
  • 2-Hr fire-tested
  • Meets UL142 and NFPA30 requirements
  • Emergency vent, size determined by tank capacity
  • Stack vent, size determined by tank capacity
  • 4" Fuel fill port with 7 gallon overspill containment and lockable cap
  • Krueger At-a-Glance fuel gauge
  • 4" fitting with 1.5" fuel pickup fitting with drop tube and foot valve, set 6" from bottom of tank
  • 4" fitting for fuel return
  • 2 x 4" Spare fittings
  • Float vent valve (during filling operation, signals when tank is reaching filled condition)
  • Engineered hurricane tie downs
  • SP-6 blast with 5-7 mils polyurethane coat (optional finishes available for superior corrosion protection)
  • Required decals and placards
  • Krueger Leak Gauge, interstitial leak monitor,
  • Ladder for easy tank access
  • 30-Year warranty by Steel Tank Institute
  • Double wall, cylindrical or rectangular construction
  • 2-Hr fire-tested
  • Meets UL142 and NFPA30 requirements
  • Emergency vent, size determined by tank capacity
  • Stack vent, size determined by tank capacity
  • Clay & Bailey overfill prevention valve
  • Morrison Clock Gauge/Hi Level Alarm
  • Moisture Pump (for removal of water in bottom of tank)
  • Ladder for easy tank access
  • Krueger Leak Gauge, interstitial leak monitor,
  • Engineered Hurricane Tie Downs
  • 4" fitting with 1.5" fuel pickup fitting with drop tube and foot valve, set 6" from bottom of tank
  • 4" fitting for fuel return
  • 2 x 4" Spare fittings
  • SP-6 blast with 5-7 mils polyurethane coat (optional finishes available for superior corrosion protection)
  • Required decals and placards
  • Ground loading with ball and check valve, and
    3" coupling with locking dust cap
  • 30-Year Warranty by Steel Tank Institute
Flameshield
Model
Capacity
(gallons)
Vent Size
(stack/emergency)
Diameter Length Weight
(approx, lbs.)
FS-500

500

2" / 4"

48"

6’5"

1,825

FS-1000

1,000

2" / 4"

48"

12’9"

2,950

FS-2000

2,000

2" / 4"

65"

14’0"

4,400

FS-3000

3,000

2" / 4"

65"

20’0"

6,250

FS-4000

4,000

2" / 4"

65"

26’0"

7,950

FS-5000

5,000

2" / 8"

97"

17’10"

10,350

FS-6000

6,000

2" / 8"

97"

20’6"

12,450

FS-8000

8,000

2" / 8"

97"

25’10"

14,750

FS-10000

10,000

2" / 8"

97"

31’2"

17,500

FS-12000

12,000

2" / 8"

97"

36’6"

21,500

FS-15000

15,000

2" / 8"

97"

44’6"

24,000

FS-20000

20,000

2" / 8"

127"

35’6"

32,250

Request E-Quote

Fireguard Features:
200-4,000 gallon capacity
Fireguard Features:
5,000-25,000 gallon capacity
  • "Protected" double wall, cylindrical construction
  • 2-Hr fire-tested, ballistic and vehicle impact tested.
  • Meets UL2085, UL2080, UL142 and NFPA30 requirements
  • Emergency vent, size determined by tank capacity
  • Stack vent, size determined by tank capacity
  • 4" Fuel fill port with 7 gallon overspill containment with lockable cap
  • Krueger At-a-Glance fuel gauge
  • 4" fitting with 1.5" fuel pickup fitting with drop tube and foot valve, set 6" from bottom of tank
  • 4" fitting for fuel return
  • 2 x 4" Spare fittings
  • Float vent valve (during filling operation, signals when tank is reaching filled condition)
  • Engineered hurricane tie downs
  • SP-6 blast with 5-7 mils polyurethane coat (optional finishes available for superior corrosion protection)
  • Required decals and placards
  • Krueger Leak Gauge, interstitial leak monitor.
  • Ladder for easy tank access
  • 30-Year warranty by Steel Tank Institute
  • "Protected" double wall, cylindrical construction
  • 2-Hr fire-tested, ballistic and vehicle impact tested.
  • Meets UL2085, UL2080, UL142 and NFPA30 requirements
  • Emergency vent, size determined by tank capacity
  • Stack vent, size determined by tank capacity
  • Clay & Bailey overfill prevention valve
  • Morrison Clock Gauge/Hi Level Alarm
  • Moisture Pump
  • Ladder for easy tank access
  • Krueger Leak Gauge, interstitial leak monitor.
  • Engineered Hurricane Tie Downs
  • 4" fitting with 1.5" fuel pickup fitting with drop tube and foot valve, set 6" from bottom of tank
  • 4" fitting for fuel return
  • 2 x 4" Spare fittings
  • SP-6 blast with 5-7 mils polyurethane coat (optional finishes available for superior corrosion protection)
  • Required decals and placards
  • Ground loading with ball and check valve, and 3" coupling with locking dust cap
  • 30-Year Warranty by Steel Tank Institute
Fireguard
Model
Capacity
(gallons)
Vent Size
(stack/emergency)
Diameter Length Weight
(approx, lbs.)
FG-500

500

2" / 4"

58"

6’5"

3,100

FG-1000

1,000

2" / 4"

54"

12’9"

5,800

FG-2000

2,000

2" / 4"

70"

14’0"

6,500

FG-3000

3,000

2" / 4"

70"

20’0"

9,000

FG-4000

4,000

2" / 4"

70"

26’0"

12,300

FG-5000

5,000

2" / 8"

102"

17’10"

13,750

FG-6000

6,000

2" / 8"

102"

20’6"

15,500

FG-8000

8,000

2" / 8"

102"

25’10"

20,000

FG-10000

10,000

2" / 8"

102"

31’2"

24,500

FG-12000

12,000

2" / 8"

102"

36’6"

28,000

FG-15000

15,000

2" / 8"

102"

44’6"

34,500

FG-20000

20,000

2" / 8"

132"

35’6"

39,500

Request E-Quote